Sonic-Pro™ Hybrid Ultrasonic Flow Meters

If you cannot find the part number in the documentation please provide detail. Specific to this item, it could include part number or application detail, (ex. 20 meters of cable, or 20 litres of volume)

The Sonic Pro ultrasonic flow meters provide accurate and trouble free flow metering for a wide range full pipe applications including: potable water, raw wastewater, effluent, well water, slurries, or virtually any sound conducting liquid. The Sonic Pro ultrasonic flow meter incorporates the latest ultrasonic technology to give you an accurate, easy to use hybrid flow meter with selectable Doppler or transit-time operating modes. With its quick and easy clamp-on transducer installation, factory pre-configuration and user programmable menu driven interface, the ultrasonic flow meter is a snap to commission in the field. The reliable SONIC PRO ultrasonic flow meters use custom algorithms and DSP technology to ensure high accuracy flow metering, and the proprietary AGC (Automatic Gain Control) algorithm eliminates the need for manual gain adjustments.

Ultrasonic flow meters that use transit time and Doppler methods to measure flow.

How The Ultrasonic Flow Meters Work
The Sonic-Pro series Hybrid Ultrasonic Flow Meters can measure fluid flow in virtually any fluid in which sound waves can travel. The Ultrasonic Flow Meters are considered "hybrid" because they can measure fluid flow using either the Doppler or Transit Time methods. The Sonic-Pro ultrasonic flow meter's sound transducers are clamped to the outside of the pipe wall and include no moving parts. This method of flow measurement is safe, non-intrusive and very easy to service.

The Ultrasonic Flow Meter's Doppler measurement method requires particles be present in the flow stream to "reflect" the sound waves. The meter may be operated in the Doppler mode when the fluid contains particles.

The Ultrasonic Flow Meter's Transit Time measuring method requires relatively "clean" fluid to enable the sound waves to complete their circuit. The Ultrasonic Flow Meters may be operated in the Transit-Time mode when the fluid contains particles. To allow for changes in the fluid's particle count, the Sonic-Pro Ultrasonic Flow Meters monitor the signal gain and employ an Automatic Gain Control (AGC) algorithm that periodically adjusts the gain to maintain the optimum power level.

The speed at which sound travels in the fluid must be known. The factory will configure the meter for a known fluid during the initial configuration. The Sonic-Pro Ultrasonic Flow Meters include a 5-button user interface that can be used to configure the meter. Many common fluids are listed in The Ultrasonic Flow Meter's software and can be selected directly from the menu. Provided the speed of sound in the fluid is known, custom "unknown" fluids can be input manually by the user. A list of various fluids and their sound speeds are provided in the ultrasonic flow meter's user manual.

• Clean or dirty water applications with selectable modes
• Quick and easy set-up and operation
• Clamp-on transducers never contact process liquid
• Built in data logger downloads to standard SD card
• Fully configurable analogue and pulse outputs

Ultrasonic Flow Meter's Great Features
Loaded with the features, the SONIC PRO ultrasonic flow meters include: five programmable and password protected configurations for multiple user and portable applications, an easy to read 320 x 240 pixel backlit LCD display, data logging to standard SD Card format (user configurable to time interval, flow rate and total set-point triggers), isolated 4-20mA analogue and 0-1000Hz pulse outputs.

Ultrasonic Flow Meter's Optional Features
Optional features include: three configurable relay outputs and a communications package that allows the ultrasonic flow meter to connect to your computer via RS-232, RS-485, USB or Ethernet. The ultrasonic flow meter's communication package also permits remote access and control of all functions including real-time display, system configuration, data logging, remote data capture and process control functions. The software included with the ultrasonic flow meter's communication package allows remote internet access through a local network set-up.

Custom Configured Ultrasonic Flow Meters
The SONIC PRO ultrasonic flow meters can be configured for your specific pipe and process liquid application so that it is ready to go out of the box. We will need the following information for configuration purposes:

- Pipe size (ID), material and schedule (e.g. 3" schedule 40 PVC)
- Process liquid being measured (e.g. raw wastewater)
- Volumetric and time units to be displayed (e.g. US gallons/minute)
- Language displayed (e.g. English)

SPECIFICATIONS
Measuring principle: Ultrasonic Doppler or transit time via pipe mounted transducers
Condition of flow: Full pipe within the minimum and maximum velocity specifications
Liquid types: Virtually any acoustically conductive fluid
Transit time mode: from 0% to 1% (0 to 10,000 ppm) particulate
Doppler mode: from 0.02% to 15% (200 to 150,000 ppm) of 100 micron particulate
Nominal pipe sizes: 0.5 inch - 12.0 inch (20mm to 315mm)
Pipe materials: Most metal and plastic pipes
Pipe liner materials: Most plastic liners
Liquid velocity range: 0 to 30 f/s (0 to 9 m/s)

Accuracy at pipe inside diameter:
Flow rate averaging time (5.0s):
+1% of rate >8 ft/s and +0.06 ft/s <8 ft/s (Transit time 1/2" to 1")
+1% of rate >1 ft/s and +0.01 ft/s <1 ft/s (Transit time 1-1/4" to 12")
Flow rate averaging time (1.0s):
+1% of rate >12 ft/s and +0.12 ft/s <12 ft/s (Transit time 1/2" to 1")
+1% of rate >5 ft/s and +0.05 ft/s <5 ft/s (Transit time 1-1/4" to 12")
Flow rate averaging time (0.5s):
+2% of rate >12 ft/s and +0.25 ft/s <12 ft/s (Transit time 1/2" to 1")
+2% of rate >12 ft/s and +0.25 ft/s <12 ft/s (Transit time 1-1/4" to 12")

Electronics & Interface
Power: 90-264 VAC 50/60Hz or 15-30 VDC @ 40 watts maximum
Display: 320 x 240 pixel QVGA backlit LCD, UV resistant.
Rate and total display: 10 digit maximum + exponent to E+32 (selectable decimal location)

Display languages: English, Spanish, French or German selectable
Keypad: Five-button positive action tactile switch keypad
Security: Master password and individual configuration passwords

Rate & flow units: Independently configurable rate and total display units in: US Gallons, ounces, barrels (US liquid), barrels (US oil), cubic feet, acre feet, Imperial (British) gallons, liter, cubic meter, or user defined "custom" units.
Display time units: Seconds, minutes, hours, days (rate & total units are independent)

Display outputs
Update time: Selectable: 0.25, 0.50, 1.0 (default), 2.5, 5.0 seconds
Rate averaging: Selectable: 0.50, 1.0, 2.5, 5.0 (default), 10.0 seconds

Signal outputs
Analog: Isolated 4-20 mA output - fully configurable, invertible
Pulse: 0-1000 Hz Pulse output - fully configurable, invertible
Control/alarm outputs: Three independently configurable 10 amp Form C, NO/NC relays

Data Logging
Rate & total: Date/time stamped in FAT32 file format, easily imported into Excel
Settings: Trigger on time interval (1-999,999 sec), rate and/or total set-point values
Storage: Over 30,000 events with included 32MB SD Card

Environmental
Enclosure: NEMA 4X (IP66), powder coated aluminum, stainless steel hardware
Dimensions: 11.00H x 8.60W x 5.00D inches (279H x 218W x 127D mm)
Weight: 6.8 lb. (3.1 kg)
Mounting: Wall, pipe (vertical or horizontal) or panel Hardware included
Panel opening: 10.63H x 8.10W inches (270H x 206W mm)
Panel depth: rear: 2.78 inches (71 mm), front: 2.18 inches (55 mm)
Operating temperature: 14 to 140° F (-10 to 60° C)
Storage temperature: -40 to 158° F (-40 to 70° C)

External Communications
Computer connection: RS-232, RS-485, USB, Ethernet (comm. software included)

Clamp-On Transducers
Housing: NEMA 4X (IP66), powder coated aluminum, stainless steel hardware
Dimensions: 3.12H x 2.95W x 1.60D inches (79H x 75W x 41D mm)
Weight: 0.8 lb. (0.4 kg.) each
Cable: Shielded coaxial RG/U 59, PVC jacket, RoHS Compliant. Standard length: 10 ft. (3m)
Optional lengths available: 25 ft. (7m), 50 ft. (15m), 100 ft. (30m)
Nominal Pipe Sizes
A series transducer: 0.5 inch - 2.0 inch (20mm to 63mm)
B series transducer: 2.0 inch - 12.0 inch (63mm to 300mm)
Pipe surface temp: 14 to 212° F (-10 to 100° C)

Ultrasonic Flow Meters Options

SONIC PRO Ultrasonic Flow Meter
Transit time/Doppler flowmeter with datalogger & 10 FT cable

SONIC PRO -B 3-relay option (for control and alarms)
SONIC PRO -A Smart communications/configuration package
SONIC PRO -25 25 FT transducer cable (for 2 transducers)
Please specify the pipe diameter to be used with the transducers.
SONIC PRO -50 50 FT transducer cable (for 2 transducers)
Please specify the pipe diameter to be used with the transducers
SONIC PRO -100 100 FT transducer cable (for 2 transducers)

Please specify the pipe diameter to be used with the transducers.